THE-600 room humidity and temperature sensor and transmitter with LCD for HVAC, offering 0–100 %RH measurement and analogue or Modbus RTU options. It provides room-condition measurement for a compatible building automation controller. Specify the required output combination and confirm the display configuration before ordering.
Room humidity and temperature sensor and transmitter with LCD.
Humidity measuring range: 0–100 %RH.
Catalogue temperature range: −40 to +140 °C (−40 to +284 °F).
Conformal coating for sensing-element protection.
0–10 V, 0–5 V, 4–20 mA, passive temperature and Modbus RTU options.
IP30 protection rating.
| Parameter | THE-600 |
|---|---|
| Product type | Room Humidity & Temperature Sensor & Transmitter |
| Humidity measuring range | 0–100 %RH |
| Temperature measuring range | −40 to +140 °C (−40 to +284 °F) |
| Sensing-element protection | Conformal coating |
| Output options | 0–10 V / 0–5 V / 4–20 mA / passive temperature sensor |
| Digital interface option | Modbus RTU |
| Display | LCD |
| Protection rating | IP30 |
The output signals are options for different versions, not simultaneous outputs from every unit. Passive sensing applies to temperature. Confirm the configured temperature range, humidity signal, temperature signal and LCD availability for the selected configuration.
The THE-600 room humidity transmitter provides humidity and temperature inputs for HVAC monitoring and building automation in indoor spaces. The LCD-equipped model can be selected where a local display is required. Match the signal to the BMS, DDC or PLC and choose a representative room location suitable for IP30 protection.
Select 0–10 V or 0–5 V to match the controller’s voltage input range, or 4–20 mA for a compatible current input. The English manual identifies three-wire current output as standard and a two-wire version as a customized option. Confirm the supply and connection arrangement for the supplied unit.
The manual lists NTC 10 kΩ, NTC 20 kΩ, Pt100 and Pt1000 passive temperature options, and RS-485 / Modbus RTU for digital communication. Specify the exact controller input requirement; passive temperature does not describe the humidity output.
The catalogue lists measurement and signal options, not stand-alone setpoint control or relay outputs. Use a suitable connected controller for control actions unless another configuration is confirmed.
The THE-600 English manual lists ±3 %RH humidity accuracy and ±0.3 °C temperature accuracy. Confirm the applicable operating point and selected version for the required tolerance rather than assuming these values apply uniformly over the entire catalogue range.
The catalogue rating is IP30. Conformal coating and a 0–100 %RH measuring range do not make the room enclosure waterproof. Confirm operating conditions and condensation suitability before selecting it for a damp or exposed location.
The English manual states three-wire as standard, with a two-wire version available by customization. Specify the required arrangement and confirm the supplied version’s power and connection requirements.
Confirm both when ordering. The configured analogue range must match the controller’s scaling; the full catalogue range should not be assumed for every version. Confirm LCD operation for the selected signal combination, particularly a passive-temperature configuration.
For analogue versions, match the controller input and signal scaling. For a passive temperature input, match the sensing element. For Modbus RTU, confirm the communication settings and register information for the supplied unit. Choose a room position away from unrelated local heat sources or drafts that could bias the measurement.
MOQ: 5 pcs. Send your room application, humidity and temperature conditions, required output combination, LCD requirement, controller input and quantity to info@heatcoolsmart.com.
Other room and remote-probe formats: THE-500 room model and THE-300 remote probe.