THE-200 duct or wall-mount humidity and temperature sensor and transmitter, with 0–100 %RH measurement and analogue or Modbus RTU output options. Select the installation method and signal combination to match the HVAC or building automation application. Passive temperature sensing is available as a version option.
Duct or wall-mount humidity and temperature measurement.
Humidity range: 0–100 %RH.
Catalogue temperature range: −40 to +140 °C (−40 to +284 °F).
Conformal coating for sensing-element protection.
0–10 V, 0–5 V, 4–20 mA, passive temperature and Modbus RTU options.
Housing IP65 / probe IP30.
| Parameter | THE-200 |
|---|---|
| Product type | Duct / Wall-Mount Humidity & Temperature Sensor & Transmitter |
| Humidity measuring range | 0–100 %RH |
| Temperature measuring range | −40 to +140 °C (−40 to +284 °F) |
| Sensing-element protection | Conformal coating |
| Output options | 0–10 V / 0–5 V / 4–20 mA / passive temperature sensor |
| Digital interface option | Modbus RTU |
| Mounting options | Wall mount / duct mount |
| Protection rating | Housing IP65 / Probe IP30 |
The signals are version options, not simultaneous outputs from every unit. The passive option applies to temperature sensing. Confirm the configured measuring range, signal combination and mounting arrangement when ordering.
The THE-200 humidity and temperature transmitter supports HVAC air monitoring and building automation applications using wall or duct mounting. Select a location representative of the air being measured and match the signal to the controller input. The housing and probe have different protection ratings, which must be considered separately.
Choose 0–10 V or 0–5 V to match a voltage input, or 4–20 mA for a compatible current input. The English manual identifies three-wire current output as standard, with a two-wire version requiring customization. Confirm the supplied configuration before connection.
For a passive temperature input, the manual lists NTC 10 kΩ, NTC 20 kΩ, Pt100 and Pt1000 options. For digital communication, it lists RS-485 / Modbus RTU. Confirm the exact sensing element or communication configuration needed by the BMS, DDC or PLC.
Choose according to where the air condition must be measured and the available mounting arrangement. The catalogue lists both formats for THE-200. Specify the intended installation so the suitable supplied configuration can be confirmed.
THE-100 is listed for duct mounting; THE-200 lists wall or duct mounting. Select using the mounting requirement and probe arrangement, and confirm the signal version separately rather than assuming similar housings mean identical installation details.
The THE-200 English manual lists ±3 %RH humidity accuracy and ±0.3 °C temperature accuracy. Confirm the applicable conditions, operating point and selected version for your required tolerance. Do not assume these figures apply uniformly over the entire catalogue range.
No. The catalogue lists −40 to +140 °C, but the configured analogue range must be specified for the ordered version and matched to the controller. The manual uses separate range selections; do not assume every unit uses the full catalogue span.
The catalogue specifies housing IP65 and probe IP30. Conformal coating and a 0–100 %RH measuring range do not establish that the probe is waterproof or suitable for immersion or condensation. Check the environment for the actual installation.
No. The English manual states three-wire as standard and two-wire by customization. Specify the required arrangement and confirm the power and connection requirements for the supplied version.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the mounting method, expected humidity and temperature conditions, required output combination, controller input and quantity.