SAE-960 8-in-one air quality sensor with LCD and Modbus RTU for humidity, temperature, CO2, CO, PM2.5, PM10, TVOC and HCHO monitoring. It combines the eight catalogue-listed parameters in one product format for compatible building automation monitoring. Confirm the supplied sensor configuration, display values and firmware-specific data mapping.
Eight parameters: humidity, temperature, CO₂, CO, PM2.5, PM10, TVOC and HCHO.
Modbus RTU digital interface.
LCD display listed in the catalogue.
15–35 V DC / 24 V AC power supply.
IP30 protection for suitable indoor installations.
| Parameter | SAE-960 catalogue range |
|---|---|
| Relative humidity | 0–100 %RH |
| Temperature | −40 to +140 °C (−40 to +284 °F) |
| Carbon dioxide (CO₂) | 0–2000 ppm |
| Carbon monoxide (CO) | 0–1000 ppm |
| PM2.5 | 0–1000 µg/m³ |
| PM10 | 0–1000 µg/m³ |
| TVOC | 0–1000 ppb |
| Formaldehyde (HCHO) | 0–1000 ppb |
| Parameter | Specification |
|---|---|
| Product type | 8-in-One Air Quality Sensor |
| Digital interface | Modbus RTU |
| Power supply | 15–35 V DC / 24 V AC |
| Display | LCD |
| Protection rating | IP30 |
The catalogue lists Modbus RTU and does not list analogue outputs for SAE-960. Confirm the enabled parameters, display arrangement, power and connection requirements for the supplied configuration.
The SAE-960 multi-parameter air quality sensor provides room-condition and air-quality information for a compatible building automation system. A connected controller can use the measurements for monitoring and system decisions according to the installation design. Select an indoor environment suitable for IP30 protection.
Before integration, obtain the exact communication settings, register map, units, scaling and data formats for all eight parameters. Match the controller configuration to the supplied firmware. The measuring ranges do not establish accuracy, response time or environmental limits for the complete unit.
Humidity, temperature, CO₂, CO, PM2.5, PM10, TVOC and HCHO are counted separately. PM2.5 and PM10 are two particulate parameters, even though the catalogue groups their range on one row.
The SAE-960 catalogue entry lists Modbus RTU only. Do not copy analogue output options from the single-parameter SAE models. Specify any analogue requirement for separate confirmation.
The SAE-960 entry lists 0–2000 ppm. The 0–5000 ppm option shown for other CO₂ models must not be assumed for this unit.
These are not stated in the SAE-960 catalogue entry. Provide the operating points and required tolerances, and request performance data for each measurement. Do not combine specifications from separate single-parameter models.
The catalogue lists LCD but does not define its display pages or update behaviour. Confirm which values are shown and how they are accessed for the supplied version.
The catalogue does not state safety-alarm or compliance-testing certification. Confirm the requirements of the complete installation; the presence of multiple measurements does not establish those functions.
MOQ: 5 pcs. Send the application, required measurements, operating conditions, controller communication requirements, display needs and quantity to info@heatcoolsmart.com.
For dedicated particulate measurement, see SAE-360; for dedicated CO₂ measurement, see SAE-260.