THE-500 Room Humidity & Temperature Sensor and Transmitter | iCoolheat

THE-500 Room Humidity & Temperature Sensor and Transmitter | iCoolheat 1
  • THE-500 Room Humidity & Temperature Sensor and Transmitter | iCoolheat 1
  • Place of Origin:China
  • Brand Name:iCoolheat
  • MOQ:5 pcs
  • Packaging Details:Standard Export Carton
  • Payment Terms:T/T
  • Supply Ability:20,000 pcs/month
  • Lead Time:7 days for standard models

THE-500 room humidity and temperature sensor and transmitter for HVAC, with LCD, 0–100 %RH measurement and analogue or Modbus RTU output options. It provides humidity and temperature information for a compatible building automation controller. Select the output combination and confirm the LCD configuration before ordering.

Key features

  • Room humidity and temperature measurement for HVAC monitoring.

  • Humidity range: 0–100 %RH.

  • Catalogue temperature range: −40 to +140 °C (−40 to +284 °F).

  • Conformal coating for sensing-element protection.

  • 0–10 V, 0–5 V, 4–20 mA, passive temperature and Modbus RTU options.

  • LCD listed in the catalogue; IP30 protection.

Technical specifications

ParameterTHE-500
Product typeRoom Humidity & Temperature Sensor & Transmitter
Humidity measuring range0–100 %RH
Temperature measuring range−40 to +140 °C (−40 to +284 °F)
Sensing-element protectionConformal coating
Output options0–10 V / 0–5 V / 4–20 mA / passive temperature sensor
Digital interface optionModbus RTU
DisplayLCD
Protection ratingIP30

The listed outputs are version options, not simultaneous signals from every unit. Passive sensing applies to temperature. The catalogue image shows plain-front and LCD-front appearances; confirm the ordered display and output configuration.

Applications

The THE-500 room humidity transmitter can provide humidity and temperature inputs for HVAC and building automation in occupied indoor spaces, subject to the selected version’s operating conditions. It can support room-condition monitoring by a compatible BMS, DDC or PLC. Use a representative room location and an environment suitable for IP30 protection.

Choosing the output

Match a 0–10 V or 0–5 V version to the controller’s voltage input range, or select 4–20 mA for a compatible current input. Confirm the humidity and temperature signal arrangement and scaling. For passive temperature sensing, specify the exact element and resistance characteristic required by the controller. For Modbus RTU, obtain the supplied version’s communication settings and register information.

Selection questions

Is THE-500 also a room thermostat or humidistat?

The catalogue identifies it as a humidity and temperature sensor and transmitter. It does not specify stand-alone setpoint control or switching relays. Control actions require a suitable connected controller unless another configuration is confirmed.

Does the catalogue image mean I receive two units?

No package quantity is established by the image. It illustrates plain-front and LCD-front appearances. Specify the required display configuration and quantity when requesting a quotation.

Can I use it in a damp room or outdoors?

The protection rating is IP30. The humidity measuring range and conformal coating do not make the enclosure waterproof. Confirm the environment and condensation conditions for the supplied version before use in damp or exposed locations.

What accuracy does THE-500 provide?

The THE-500 catalogue entry does not state accuracy. Provide the humidity and temperature operating points and required tolerances so performance can be confirmed for the selected version. Do not apply another model’s accuracy to this product.

Where should I position the room sensor?

Choose a location representative of the air being monitored. Consider sunlight, nearby heat sources and supply-air drafts that could make readings unrepresentative. Follow the mounting instructions supplied with the selected configuration.

Does passive sensing provide humidity and temperature?

The passive option refers to temperature sensing. Specify the required humidity signal separately, and confirm the complete output arrangement and controller compatibility before ordering.

Request a quotation

MOQ: 5 pcs. Email info@heatcoolsmart.com with the room application, expected humidity and temperature conditions, required outputs, LCD requirement and quantity.

For duct or remote-probe applications, see THE-100 duct mount and THE-300 remote probe.