THE-300 Remote Probe Humidity & Temperature Sensor | iCoolheat

THE-300 Remote Probe Humidity & Temperature Sensor | iCoolheat 1
  • THE-300 Remote Probe Humidity & Temperature Sensor | iCoolheat 1
  • Place of Origin:China
  • Brand Name:iCoolheat
  • MOQ:5 pcs
  • Packaging Details:Standard Export Carton
  • Payment Terms:T/T
  • Supply Ability:20,000 pcs/month
  • Lead Time:7 days for standard models

THE-300 remote probe humidity and temperature sensor and transmitter for HVAC, with 1–2 m cable options, 0–100 %RH measurement and Modbus RTU options. The remote probe allows the sensing location to be separated from the housing. Choose the cable length and output combination to suit the measurement point and connected controller.

Key features

  • Remote probe for humidity and temperature measurement.

  • Humidity measuring range: 0–100 %RH.

  • Temperature measuring range: −40 to +140 °C (−40 to +284 °F).

  • Conformal coating for sensing-element protection.

  • 0–10 V, 0–5 V, 4–20 mA, passive temperature and Modbus RTU options.

  • Cable length: 1–2 m; housing IP65 / probe IP30.

Technical specifications

ParameterTHE-300
Product typeHumidity & Temperature Sensor & Transmitter with Remote Probe
Humidity measuring range0–100 %RH
Temperature measuring range−40 to +140 °C (−40 to +284 °F)
Sensing-element protectionConformal coating
Output options0–10 V / 0–5 V / 4–20 mA / passive temperature sensor
Digital interface optionModbus RTU
Cable length1–2 m
Protection ratingHousing IP65 / Probe IP30

These signals are version options, not simultaneous outputs from every unit. Passive sensing refers to temperature. Confirm the supplied cable length, output combination and configured measuring range before ordering.

Applications

The THE-300 remote humidity and temperature sensor is suitable for HVAC and building automation applications where the sensing point needs to be located away from the housing. Position the probe to represent the air being monitored, and place the housing where it can be mounted and accessed appropriately. Check the environment against the separate probe and housing protection ratings.

Output and cable selection

Match 0–10 V, 0–5 V or 4–20 mA to the controller’s supported analogue input and scaling. For passive temperature sensing, confirm the required sensing element and resistance characteristic. For Modbus RTU, obtain the supplied version’s communication settings and register information.

The listed cable length is 1–2 m. Specify the required supplied length and routing needs. Do not assume that a longer cable, a field extension or a replacement probe is interchangeable without confirmation.

Selection questions

When should I choose THE-300 instead of THE-100 or THE-200?

Choose the remote-probe layout when the measurement point and housing need to be separated. THE-100 is listed for duct mounting and THE-200 for wall or duct mounting. Check the installation arrangement rather than choosing solely by similar housing appearance.

Can I order a cable longer than 2 m?

The catalogue lists 1–2 m. Ask for confirmation of any longer or non-standard configuration, including the suitability of the probe, cable and signal version for the installation.

Does the IP65 housing make the probe waterproof?

No. The catalogue gives the probe an IP30 rating and the housing an IP65 rating. The humidity range and conformal coating do not establish suitability for immersion, water spray or condensation at the probe.

Does passive sensing cover both humidity and temperature?

The passive option is identified for temperature sensing. Specify the required humidity output separately and confirm how both measurements are provided in the ordered configuration.

What accuracy does THE-300 provide?

The THE-300 catalogue entry does not state accuracy. Provide the humidity and temperature operating points and required tolerances so performance can be confirmed for the selected version. Accuracy from other THE models should not be assumed for this model.

Can it connect to a BMS, DDC or PLC?

Check that the controller supports the selected voltage, current, passive-temperature or Modbus RTU interface. Match the scaling, sensing element or communication configuration to the supplied unit. Confirm its power and connection requirements before installation.

Request a quotation

MOQ: 5 pcs. Send the measurement environment, humidity and temperature conditions, required output combination, cable length and quantity to info@heatcoolsmart.com.

Other installation formats: THE-100 duct mount and THE-200 duct / wall mount.

Request Free Quote

Other Products You May Like

QUALITY · RELIABILITY · INNOVATION
Get In Touch With Us
Follow Us
Top