STE-300 remote probe temperature sensor and transmitter for HVAC, with 0.5–10 m cable options, IP65 protection and analogue, passive or Modbus RTU versions. The remote probe allows the sensing point and housing to be positioned separately. Select the cable length, output and configured temperature range for the installation.
Remote probe temperature measurement for HVAC and building automation.
Catalogue temperature range of −40 to +140 °C (−40 to +284 °F).
±0.3 °C active-output accuracy at 20 °C.
0–10 V, 0–5 V, 4–20 mA, passive sensor or Modbus RTU options.
Housing IP65 / probe IP65; cable length options from 0.5 to 10 m.
| Parameter | STE-300 |
|---|---|
| Product type | Remote Probe Temperature Sensor & Transmitter |
| Temperature measuring range | −40 to +140 °C (−40 to +284 °F) |
| Accuracy | ±0.3 °C for active output, at 20 °C |
| Output options | 0–10 V / 0–5 V / 4–20 mA / passive temperature sensor |
| Digital interface option | Modbus RTU |
| Protection rating | Housing IP65 / Probe IP65 |
| Cable length | 0.5–10 m |
The listed output signals are version options, not simultaneous outputs from every unit. Confirm the configured range and supplied cable length when ordering.
The STE-300 remote temperature sensor is suited to HVAC and building automation installations where the sensing point needs to be separated from the transmitter housing. Select the probe location to represent the temperature being monitored, and position the housing where it can be mounted and maintained appropriately.
Match a 0–10 V, 0–5 V or 4–20 mA version to the controller’s analogue input and temperature scaling. For a passive temperature sensor, confirm the required sensing element and resistance characteristic. For Modbus RTU, confirm controller compatibility and obtain the communication settings and register information for the supplied version.
Choose a supplied cable length within the catalogue’s 0.5–10 m range to suit the route between the probe and housing. Allow for routing and mounting; do not assume field extension or cable substitution is permitted without confirmation.
Choose the STE-300 when the measurement location and housing location need to be separated. The STE-200 is listed for wall mounting, while the STE-100 is listed for duct or immersion mounting. Select the installation format for the application rather than relying on similar housing appearance.
The catalogue lists 0.5–10 m. Specify the length required for your installation and confirm availability of that supplied configuration. This range does not by itself confirm that an existing cable can be extended.
The catalogue specifies ±0.3 °C for active output at 20 °C. It does not state the same accuracy for every passive element or across the complete temperature range.
Check the controller’s supported input before selecting voltage, current, passive sensing or Modbus RTU. Confirm the scaling for analogue signals, the exact element for passive sensing, or the communication configuration for a digital version.
The catalogue gives the probe and housing an IP65 rating, not a continuous-submersion rating. Confirm the installation and medium suitability before selecting it for contact with liquids.
Provide the operating temperature range, output type, cable length, installation environment and quantity. Confirm any special probe or installation requirements before purchase.
MOQ: 5 pcs. Send your application, temperature range, output, cable length and quantity to info@heatcoolsmart.com.
Other installation formats: STE-100 duct / immersion and STE-200 wall mount.