SLT-100 submersible level transmitter with 1–5 m range options, ±0.5 %FS accuracy, IP68 protection and voltage, 4–20 mA or RS-485 output options. Select the full-scale level range and output to match the monitoring application. Power requirements depend on the chosen output version.
Submersible level transmitter with five catalogue range options.
0–1 m, 0–2 m, 0–3 m, 0–4 m or 0–5 m.
Accuracy: ±0.5 % FS.
0–10 V, 0–5 V, 4–20 mA or RS-485 options.
Operating temperature: −20 to +85 °C.
IP68 protection rating.
| Parameter | SLT-100 |
|---|---|
| Product type | Submersible Level Transmitter |
| Accuracy | ±0.5 % FS |
| Analogue output options and codes | 0–10 V (1) / 0–5 V (2) / 4–20 mA (3) |
| Digital interface option and code | RS-485 (4) |
| Operating temperature | −20 to +85 °C |
| Protection rating | IP68 |
| Range | Catalogue code |
|---|---|
| 0–1 m | -1 |
| 0–2 m | -2 |
| 0–3 m | -3 |
| 0–4 m | -4 |
| 0–5 m | -5 |
| Selected output | Required supply listed in catalogue |
|---|---|
| 0–5 V / 4–20 mA | 8–36 V DC |
| 0–10 V | 12–36 V DC |
| RS-485 | 10–30 V DC |
Outputs and ranges are selection options, not simultaneous outputs or automatically selectable spans from every unit. Confirm the exact range, signal and supply of the ordered version.
The SLT-100 provides a level measurement input for compatible liquid-level monitoring installations. Select the range to cover the required measurement depth, and confirm the liquid properties, material compatibility, cable length and installation arrangement before purchase.
Match the voltage or current output and configured level scaling to the controller. For RS-485, request the actual communication protocol and data definitions; the catalogue lists the interface without identifying Modbus RTU.
Choose one of the listed full-scale ranges to cover the required level span. Specify the maximum measurement depth and installation conditions, and confirm any overload or allowable immersion conditions separately.
FS refers to the selected full-scale span, not a percentage of the current reading. Confirm reference conditions for the actual version. The same percentage of a larger selected span corresponds to a larger absolute level value.
No. The catalogue lists 8–36 V DC for 0–5 V and 4–20 mA, 12–36 V DC for 0–10 V, and 10–30 V DC for RS-485. Match the power supply to the selected output version.
No. IP68 is the listed protection rating; the selected measuring range and permitted immersion conditions must still suit the installation. Confirm cable-end sealing and installation requirements for the supplied version.
They are different selection requirements. The catalogue lists measuring ranges but does not give supplied cable lengths. Specify both the required level span and the cable route length when ordering.
The catalogue specifies RS-485 only. Confirm the protocol, settings and data definitions before connecting it to a BMS, PLC or other controller.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the liquid, maximum level, temperature, required range, cable length, output, available DC supply and quantity.