PTE-100 water pressure transmitter with a 0–16 bar range, 1/4 NPT connection and voltage, 4–20 mA or RS-485 options for compatible liquids and gases. Select the output and range for the pressure-monitoring application. The PTE-1003 reference instructions apply to the 4–20 mA version; other versions require their own electrical confirmation.
Water pressure transmitter with a catalogue range of 0–16 bar.
Custom ranges available on request.
Accuracy class 0.5.
0–10 V, 0–5 V, 4–20 mA or RS-485 options.
1/4 inch NPT process connection.
For liquids and gases compatible with 304 stainless steel.
| Parameter | PTE-100 |
|---|---|
| Product type | Water Pressure Transmitter |
| Measuring range | 0–16 bar |
| Custom ranges | Available on request |
| Accuracy class | 0.5 |
| Analogue output options and codes | 0–10 V (1) / 0–5 V (2) / 4–20 mA (3) |
| Digital interface option and code | RS-485 (4) |
| Supply for 4–20 mA version | 12–36 V DC |
| Operating temperature | −20 to +85 °C |
| Process connection | 1/4 inch NPT |
| Suitable media | Liquids and gases compatible with 304 stainless steel |
Outputs are version options, not simultaneous outputs from every unit. The listed 12–36 V DC supply applies to the 4–20 mA version. Confirm the supply and protocol requirements of other versions before ordering.
The PTE-100 water pressure sensor and transmitter provides a pressure input for compatible liquid or gas systems. The PTE-1003 reference instructions include chilled-water and heating-water pressure installations. Check the medium’s compatibility with 304 stainless steel and keep the installation within the selected version’s operating conditions.
Choose 0–10 V or 0–5 V for a controller with a matching voltage input, or 4–20 mA for a compatible current input. Confirm the configured pressure span and controller scaling. The catalogue lists an RS-485 version but does not identify its application protocol; request the exact protocol and register information for the supplied version.
The PTE-1003 reference instructions recommend an isolation/service valve and a pressure buffer tube for chilled-water and heating-water installations, to manage condensation or bring temperature within the permitted operating range. Confirm the suitable arrangement for the actual system.
Protect the cable and pressure-sensitive parts. Follow the supplied maintenance instructions; do not pull the cable forcefully or press the diaphragm with tools.
The supplied PTE-1003 instructions describe the 0–16 bar, 4–20 mA configuration. The catalogue lists output code 3 for 4–20 mA in the PTE-100 family. Confirm the full ordering designation for the required version before purchase.
The catalogue specifies that supply for the 4–20 mA version. Do not extend it automatically to voltage or RS-485 versions; obtain the electrical requirements for the selected output.
Not by itself. RS-485 identifies the listed interface, while the catalogue does not state a protocol for this model. Confirm the communication protocol, settings and data definitions before integration.
The catalogue states class 0.5 without defining the full reference conditions or error calculation. Confirm its basis for the selected range and operating conditions rather than rewriting it as an unsupported accuracy formula.
They are different thread standards. Match the sensor connection to the mating fitting or specify a suitable adapter; do not assume they are interchangeable.
The catalogue limits media to liquids and gases compatible with 304 stainless steel. Check the actual medium, temperature, pressure range and any material requirements before selection.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the medium, pressure range, operating temperature, output, available power, mating connection and quantity. State any custom-range requirement.