The DPT-600 differential pressure transmitter provides a pressure measurement signal for HVAC and building automation systems. Select an analogue output or a Modbus RTU version to match the receiving controller. The DPT-600 includes an auto-zero function and has a specified accuracy of ±0.5% FS.
Measuring range: -2000 to +2000 Pa.
Accuracy: ±0.5% of full scale.
Analogue output options: 0-10 V, 0-5 V or 4-20 mA.
Digital interface option: Modbus RTU.
Auto-zero function.
IP30 protection rating.
| Parameter | DPT-600 |
|---|---|
| Product type | Differential pressure transmitter |
| Measuring range | -2000 to +2000 Pa |
| Accuracy | ±0.5% FS |
| Operating temperature | -20 to +60 °C (-4 to +140 °F) |
| Analogue output options | 0-10 V / 0-5 V / 4-20 mA |
| Digital interface | Modbus RTU |
| Feature | Auto-zero function |
| Protection rating | IP30 |
Specify the required output and calibrated range when ordering. Analogue signals and digital communication are configuration options, not a promise of simultaneous outputs.
Use the DPT-600 as a pressure measurement input in HVAC and building automation projects where its range, accuracy and environmental rating meet the system design. For cleanroom or data center monitoring, compare the required pressure tolerance with the full-scale accuracy and confirm the installation arrangement before selecting a version.
Pressure range: define the expected normal pressure and pressure excursions, then confirm the calibrated range.
Controller input: choose a voltage, current or Modbus RTU version to match the BMS or DDC controller.
Environment: check the -20 to +60 °C operating range and IP30 protection rating.
Installation: confirm the connection arrangement, supply requirements and installation details for the ordered version before installation.
Choose 0-10 V or 0-5 V for a compatible voltage input, 4-20 mA for a compatible current input, or the Modbus RTU version for a compatible digital communication system. Check the controller input specification before ordering.
Yes, Modbus RTU is an available digital interface. Specify this version in your enquiry and confirm its communication settings and register information before integration.
FS means full scale. Compare the resulting absolute pressure error for the selected calibrated range with the accuracy your project requires. It is not a percentage of each individual reading.
The specified protection rating is IP30. Do not treat it as a waterproof outdoor sensor; confirm suitable environmental protection for the installation.
Do not assume another model uses the same electrical connections. Request the DPT-600 supply and wiring information for the ordered configuration before connecting it.
Minimum order quantity: 5 pcs. For selection and pricing, send the required range, output signal, application and quantity to info@heatcoolsmart.com.
Related product: DPT-100 Differential Pressure Transmitter.