DPT-100 is an HVAC differential pressure transmitter for building automation pressure monitoring. It combines an auto-zero function with analogue output options and a Modbus RTU digital interface.
Pressure range: -2000 to +2000 Pa
Accuracy: ±0.5% FS
Analogue output options: 0-10 V, 0-5 V or 4-20 mA
Digital interface: Modbus RTU
Feature: Auto-zero function
| Parameter | DPT-100 |
|---|---|
| Product type | Differential pressure transmitter |
| Measuring range | -2000 to +2000 Pa |
| Accuracy | ±0.5% FS |
| Operating temperature | -20 to +60 °C (-4 to +140 °F) |
| Analogue output options | 0-10 V / 0-5 V / 4-20 mA |
| Digital interface | Modbus RTU |
| Zero adjustment | Auto-zero function |
| Protection rating | IP30 |
Output signals are selection options. Confirm the ordered version, calibrated range, power supply and wiring before purchase.
For HVAC and building automation projects requiring a differential-pressure input, check the required pressure range and the receiving controller input first. For cleanroom or data center projects, confirm the required accuracy, installation conditions and system requirements with the project designer.
A transmitter provides a pressure measurement signal to a controller. A switch changes its contact state at a pressure threshold. DPT-100 is a transmitter. Choose a pressure switch instead when your controller only needs a switching contact.
A Modbus RTU version is available. Specify the digital communication version when ordering and confirm its communication settings and wiring requirements.
Specify the 0-10 V, 0-5 V or 4-20 mA output required by your controller. Confirm the selected configuration when requesting a quotation; simultaneous outputs are not specified for this product offering.
FS means full scale. It is a full-scale accuracy specification rather than a percentage of each reading. Confirm the selected range and calibration details when comparing products.
The listed protection rating is IP30. Do not assume outdoor or wet-area suitability; confirm a suitable installation or protective enclosure for your project.
Select the range for your expected operating pressure and the project accuracy requirement. Because the accuracy is specified as a percentage of full scale, compare the absolute error for the selected calibrated range before ordering.
For analogue versions, match the transmitter output to the controller input: 0-10 V, 0-5 V or 4-20 mA. For a Modbus RTU version, confirm the controller supports the protocol and check the wiring, communication settings and register mapping for the ordered version.
Send your required pressure range, output signal, application and quantity to info@heatcoolsmart.com. We can help confirm the appropriate configuration before quotation.