TDE-200 Duct / Wall-Mount Dew Point Transmitter | iCoolheat

TDE-200 Duct / Wall-Mount Dew Point Transmitter | iCoolheat 1
  • TDE-200 Duct / Wall-Mount Dew Point Transmitter | iCoolheat 1
  • Place of Origin:China
  • Brand Name:iCoolheat
  • MOQ:5 pcs
  • Packaging Details:Standard Export Carton
  • Payment Terms:T/T
  • Supply Ability:20,000 pcs/month
  • Lead Time:7 days for standard models

TDE-200 duct or wall-mount dew point transmitter for HVAC, with analogue or Modbus RTU options and separate IP65 housing and IP30 probe ratings. Choose the mounting arrangement and signal to suit the air-monitoring location and connected controller. Confirm the configured dew point output scaling before ordering.

Key features

  • Dew point transmitter with duct or wall mounting options.

  • Humidity measuring range: 0–100 %RH.

  • Catalogue dew point output range: −40 to +140 °C (−40 to +284 °F).

  • Conformal coating for sensing-element protection.

  • 0–10 V, 0–5 V, 4–20 mA or Modbus RTU options.

  • Housing IP65 / probe IP30.

Technical specifications

ParameterTDE-200
Product typeDuct / Wall-Mount Dew Point Transmitter
Humidity measuring range0–100 %RH
Dew point output range−40 to +140 °C (−40 to +284 °F)
Sensing-element protectionConformal coating
Analogue output options0–10 V / 0–5 V / 4–20 mA
Digital interface optionModbus RTU
Mounting optionsWall mount / Duct mount
Protection ratingHousing IP65 / Probe IP30

The listed output signals are version options, not simultaneous outputs from every unit. Specify the required mounting arrangement, signal and configured output range.

Applications

The TDE-200 dew point transmitter can provide an input for HVAC air monitoring and building automation using duct or wall mounting. A compatible controller can use dew point information as part of a condensation-monitoring strategy according to the system design. Confirm the intended air conditions and the selected version’s measurement performance.

Mounting and output selection

Choose wall or duct mounting based on the location of the air to be monitored and the installation arrangement. Position the sensing probe where readings represent the intended air condition, with access for installation and maintenance. Consider the probe’s IP30 rating separately from the housing’s IP65 rating.

Match 0–10 V or 0–5 V to a compatible voltage input, or 4–20 mA to a current input. Set the controller scaling to match the configured dew point range. For Modbus RTU, obtain the communication settings and register information for the supplied version.

Selection questions

How is TDE-200 different from TDE-100?

TDE-100 is listed for duct mounting, while TDE-200 lists both wall and duct mounting. Choose by the installation arrangement and sensing location, then confirm the required signal version separately.

Is dew point output range the same as operating temperature or accuracy?

No. The catalogue labels −40 to +140 °C as the dew point output range. It does not state dew point accuracy or a validated operating envelope for that entire span. Provide the expected air conditions and required tolerance so suitability can be confirmed.

Can I use the humidity range as confirmation of a humidity output?

The catalogue lists a 0–100 %RH humidity measuring range, but the product is identified as a dew point transmitter. Confirm which measured values are available on the ordered analogue channels or Modbus registers rather than assuming humidity and dew point outputs are provided simultaneously.

Can it be mounted where condensation occurs?

The probe is rated IP30, while the housing is IP65. Conformal coating does not establish suitability for condensation, water spray or immersion. Confirm the environment and operating conditions for the supplied version before selection.

Does it connect directly to any BMS or PLC?

The controller must support the selected voltage, current or Modbus RTU interface. Confirm signal scaling, supply and load requirements, or communication configuration for the actual ordered version.

Is it suitable for compressed air or pressurized process gas?

The catalogue does not specify a process-pressure rating or suitability for these media. Confirm pressure, medium and performance requirements before considering an application beyond HVAC air monitoring.

Request a quotation

MOQ: 5 pcs. Email info@heatcoolsmart.com with the wall or duct installation, expected humidity and temperature conditions, dew point requirement, output type, controller input and quantity.

For the duct-only format, see TDE-100 duct dew point transmitter. For humidity and temperature measurement, see THE-200.

Request Free Quote