SAE-200 duct CO2 transmitter for HVAC monitoring, with 0–2000 or 0–5000 ppm ranges, analogue or Modbus RTU options and an IP65 housing with IP30 probe. It measures carbon dioxide concentration in HVAC duct air. Select the measuring range, output and compatible power arrangement for the connected controller.
| Parameter | SAE-200 |
|---|---|
| Product type | Duct CO₂ Transmitter |
| CO₂ measuring range options | 0–2000 ppm or 0–5000 ppm |
| Analogue output options | 0–10 V / 0–5 V / 4–20 mA |
| Digital interface option | Modbus RTU |
| Power supply | 15–35 V DC / 24 V AC |
| Mounting | Duct mount |
| Protection rating | Housing IP65 / Probe IP30 |
Ranges and output signals are selection options. Confirm the range, signal, supply compatibility and connection arrangement of the supplied version. Do not assume all signals or both measuring ranges are available simultaneously.
The SAE-200 duct CO₂ transmitter provides carbon dioxide concentration information for HVAC and building automation. A compatible controller can use the reading as part of ventilation monitoring or demand-controlled ventilation according to the system design. Select a duct location representative of the air being monitored.
| Selection | What to check |
|---|---|
| 0–2000 ppm | Check that expected concentrations fit this range and match the controller scaling. |
| 0–5000 ppm | Choose when the application requires the wider listed concentration span; confirm the required accuracy separately. |
| 0–10 V / 0–5 V | Match the controller voltage input and configured ppm scaling. |
| 4–20 mA | Check current-input compatibility and confirm supply, wiring and load requirements for the ordered version. |
| Modbus RTU | Obtain the communication settings and register definitions for the supplied version. |
Choose by the expected concentration range and controller requirements. The 5000 ppm option offers a wider listed span; the catalogue does not specify accuracy or resolution, so neither should be inferred from the range alone.
The catalogue lists two range options without stating how they are selected. Specify the required range when ordering and confirm whether the supplied version permits field changes.
No. The catalogue specifies housing IP65 and probe IP30. Confirm environmental suitability for the actual duct location, especially where condensation or water exposure may occur.
No. This catalogue entry specifies carbon dioxide measurement. It does not list particulate matter, VOC, carbon monoxide, temperature or humidity measurement for SAE-200. Select additional measurements according to the application.
No alarm function or life-safety certification is stated in the catalogue. Select it for the specified HVAC measurement application; do not assume it replaces a required safety alarm or protective system.
Match the analogue signal and ppm scaling, or the Modbus RTU configuration. The catalogue lists 15–35 V DC / 24 V AC; confirm the supplied version’s power, terminal and load requirements before connection.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the duct application, expected CO₂ concentration, required range, output, power supply and quantity.
For separate duct humidity and temperature monitoring, see THE-100.