SAE-360 room PM2.5 and PM10 transmitter with LCD, a 0–1000 µg/m³ measuring range and analogue or Modbus RTU options for indoor air-quality monitoring. It provides particulate matter concentration information for a compatible HVAC or building automation controller. Select the required output arrangement and display configuration.
Room PM2.5 and PM10 transmitter with LCD.
PM2.5 / PM10 measuring range: 0–1000 µg/m³.
0–10 V, 0–5 V or 4–20 mA analogue output options.
Modbus RTU digital interface option.
Power supply: 15–35 V DC / 24 V AC.
IP30 protection rating.
| Parameter | SAE-360 |
|---|---|
| Product type | Room PM2.5 & PM10 Transmitter |
| Measured parameters | PM2.5 and PM10 particulate matter concentration |
| PM2.5 / PM10 measuring range | 0–1000 µg/m³ |
| Analogue output options | 0–10 V / 0–5 V / 4–20 mA |
| Digital interface option | Modbus RTU |
| Power supply | 15–35 V DC / 24 V AC |
| Display | LCD |
| Protection rating | IP30 |
Signals are version options, not simultaneous outputs from every unit. Confirm the supplied PM2.5 and PM10 channel arrangement, output scaling, display configuration and power requirements.
The SAE-360 room particulate matter transmitter provides inputs for indoor air-quality monitoring in HVAC and building automation. The model-specific reference manual describes laser-scattering measurement of PM2.5 and PM10 mass concentrations. A compatible controller can use the measurements for monitoring or ventilation-system decisions according to the system design.
Match 0–10 V or 0–5 V to a compatible voltage input, or 4–20 mA to a current input. Specify whether both particulate values are needed on analogue channels and confirm the channel assignment and scaling of the selected version.
For Modbus RTU, confirm RS-485 connectivity and obtain the firmware-specific register definitions, data scaling and communication settings. Verify the electrical requirements for the supplied output and power combination.
They describe different particle-size fractions in particulate matter monitoring. The catalogue lists both concentrations in µg/m³. Specify which values the controller needs and confirm how each is provided by the selected output version.
The reference information describes PM2.5 and PM10 output channels, but the available combinations need confirmation. Specify both required signals and confirm the actual channel arrangement rather than assuming every version has two simultaneous analogue outputs.
No. It is the catalogue measuring span. Request confirmed accuracy and applicable conditions at your expected concentration. Do not infer accuracy, response time or resolution from the span alone.
The SAE-360 catalogue entry lists PM2.5 and PM10, not gas measurements. Select separate gas measurements when the application requires them; a similar enclosure does not mean the sensing functions are identical.
The protection rating is IP30. Confirm environmental suitability, condensation conditions and the required installation arrangement before selecting it for a damp or exposed location.
Confirm a representative sensing location, required airflow access, inlet and outlet arrangement, and the inspection or cleaning procedure for the supplied version. Keep the intended sensing airflow unobstructed and follow the model’s maintenance instructions.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the monitoring application, expected particulate concentrations, required PM2.5 and PM10 outputs, controller input, LCD requirement and quantity.
For separate indoor CO₂ measurement, see SAE-260 room CO₂ transmitter.