SAE-560 room HCHO formaldehyde transmitter with LCD, a 0–1000 ppb range and analogue or Modbus RTU options for indoor air monitoring. It provides a formaldehyde measurement input for a compatible HVAC or building automation controller. Specify the intended measurement conditions and required signal.
Room HCHO transmitter with LCD.
Formaldehyde measuring range: 0–1000 ppb.
0–10 V, 0–5 V, 4–20 mA or Modbus RTU options.
15–35 V DC / 24 V AC supply.
IP30 protection.
| Parameter | SAE-560 |
|---|---|
| Product type | Room HCHO Transmitter |
| Measured gas | Formaldehyde (HCHO) |
| HCHO measuring range | 0–1000 ppb |
| Analogue output options | 0–10 V / 0–5 V / 4–20 mA |
| Digital interface option | Modbus RTU |
| Power supply | 15–35 V DC / 24 V AC |
| Display | LCD |
| Protection rating | IP30 |
Output signals are alternatives for the selected version. Confirm the interface, ppb scaling, display configuration and compatible supply before ordering.
The SAE-560 formaldehyde transmitter provides a room-air monitoring input for HVAC and building automation. Select the measurement location to represent the air being monitored and confirm the selected version’s performance under the expected conditions. Monitoring or ventilation actions depend on the connected system.
Choose a voltage or current output supported by the controller and match the configured HCHO concentration scaling. For Modbus RTU, confirm communication compatibility and obtain the register definitions for the supplied firmware. Confirm power, load and connection requirements for the ordered version.
HCHO is the chemical formula used here for formaldehyde. SAE-560 is listed for this measurement; it should not be treated as a general detector for every indoor gas.
SAE-560 is listed for formaldehyde, while SAE-460 is listed for total volatile organic compounds. Choose by the measurement required, not by the similar enclosure. Confirm selectivity and any cross-sensitivity for the expected environment.
No. The catalogue gives a measuring span without accuracy, resolution or detection-limit data. Provide the required tolerance and expected concentrations so performance can be confirmed.
The catalogue does not state a certified test method or compliance certification. Confirm the measurement method, calibration and any applicable acceptance requirements before selecting it for that purpose.
Request the calibration basis, maintenance requirements and cross-sensitivity information for the supplied version. Do not assume other compounds have no effect on the reading.
Choose an indoor location representative of the target room air and suitable for IP30 protection. Confirm operating conditions and condensation suitability, and follow the supplied installation instructions.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the room application, expected HCHO concentration, required tolerance, output, available power and quantity.
For total VOC measurement, see SAE-460 TVOC transmitter.