SAE-460 room TVOC transmitter with LCD for indoor air-quality monitoring, with a 0–1000 ppb range and analogue or Modbus RTU output options. It supplies a total volatile organic compound measurement input to a compatible HVAC or building automation controller. Confirm the required output and measurement conditions for the installation.
Room TVOC transmitter with LCD.
TVOC measuring range: 0–1000 ppb.
0–10 V, 0–5 V, 4–20 mA or Modbus RTU options.
15–35 V DC / 24 V AC supply.
IP30 protection for a suitable indoor environment.
| Parameter | SAE-460 |
|---|---|
| Product type | Room TVOC Transmitter |
| TVOC measuring range | 0–1000 ppb |
| Analogue output options | 0–10 V / 0–5 V / 4–20 mA |
| Digital interface option | Modbus RTU |
| Power supply | 15–35 V DC / 24 V AC |
| Display | LCD |
| Protection rating | IP30 |
Output signals are version options, not simultaneous outputs from every unit. Confirm the selected interface, signal scaling, display configuration and supply requirements.
The SAE-460 TVOC transmitter provides a room-air measurement input for HVAC and building automation monitoring. A connected controller can use its reading within the installation’s monitoring or ventilation strategy. Confirm suitability for the expected VOC mixture and operating conditions.
Match 0–10 V or 0–5 V to the controller’s voltage input, or 4–20 mA to a compatible current input. Match the configured ppb scaling. For Modbus RTU, obtain the supplied version’s communication settings and register definitions. Confirm load and connection requirements before installation.
TVOC represents total volatile organic compound information. The catalogue does not establish identification or selective measurement of an individual compound. Provide the expected compounds and application when requesting suitability information.
SAE-460 is listed as a TVOC transmitter. Do not treat its reading as a dedicated HCHO measurement. Select the HCHO model when formaldehyde measurement is required and confirm the measurement method and performance.
A conversion depends on the compound or reference-gas basis and applicable conditions. The catalogue gives ppb, so confirm the reference basis before converting a TVOC reading into mass concentration.
The catalogue entry does not state accuracy, sensing principle or calibration-gas basis. Request confirmed performance for the expected gas mixture and concentration; do not infer it from the 0–1000 ppb span.
The listed protection is IP30. Confirm the environment, moisture and condensation conditions before selecting it for damp or exposed locations.
No alarm function or safety certification is stated in the catalogue. Treat it as a measurement transmitter for its confirmed application, not as evidence that required safety-alarm functions are provided.
MOQ: 5 pcs. Email info@heatcoolsmart.com with the application, expected VOC mixture, required output, controller input, available power and quantity.
For particulate monitoring, see SAE-360 PM2.5 and PM10 transmitter.