CTE-200 capillary frost thermostat for HVAC coil low-temperature protection, with a 1.0–7.5 °C switching range and SPDT contacts. 3 m version stocked. The adjustable frost protection switch uses a capillary sensing element to detect low-temperature conditions. Select the required capillary length and verify the contact load for the control circuit.

Key features

  • Capillary frost thermostat for low-temperature protection.
  • Adjustable switching temperature from 1.0 to 7.5 °C.
  • Switching differential: 4.5–5.5 °C.
  • SPDT contact, rated 5 (4) A at 250 VAC.
  • Catalogue capillary options: 1, 2, 3 or 4 m; the catalogue lists only the 3 m version as stocked.

Technical specifications

ParameterCTE-200
Product typeCapillary Frost Thermostat
Switching temperature range1.0–7.5 °C
Switching differential4.5–5.5 °C
Contact typeSPDT
Contact rating5 (4) A, 250 VAC
Ambient temperature−40 to +65 °C
Capillary length options and codes1 m (1) / 2 m (2) / 3 m (3) / 4 m (4)
Catalogue stock status3 m version only; confirm current availability when ordering

Applications and operating principle

The CTE-200 capillary frost protection thermostat is intended for low-temperature protection in HVAC applications. The CTE-2003 reference instructions describe use around hot-water coils, chilled-water coils and the surfaces of liquid or gas pipes.

The sensing element responds to low temperature along the capillary. The reference instructions describe the low-temperature contact opening when the temperature falls to the setpoint and reconnecting as temperature rises through the switching differential. Confirm the correct contact pair and operation for the supplied version.

Capillary length selection

LengthCatalogue codeAvailability note
1 m1Confirm availability
2 m2Confirm availability
3 m3Only stocked length listed in the catalogue
4 m4Confirm availability

Choose a length suitable for the sensing route and the area to be monitored. The capillary is a sensing element, not an ordinary extension cable; do not cut, flatten or damage it.

Selection questions

Is CTE-200 a continuous temperature transmitter?

No. The catalogue specifies an SPDT switching contact for low-temperature protection. It does not list 0–10 V, 4–20 mA or Modbus temperature output for this model.

What is the difference between switching range and differential?

The 1.0–7.5 °C range is the adjustable switching-temperature range. The 4.5–5.5 °C differential is the separation between the switching and return conditions. It is not a temperature-accuracy specification.

Does the −40 to +65 °C figure describe the setpoint range?

No. That is the listed ambient temperature range. The adjustable switching temperature remains 1.0–7.5 °C.

What does the 5 (4) A contact rating mean?

The catalogue lists 5 (4) A at 250 VAC. The CTE-2003 reference instructions identify 5 A for a non-inductive load and 4 A for an inductive load at 250 VAC. Verify the actual circuit load and the supplied switch rating before connection.

Can I order a length other than 3 m?

The catalogue lists 1, 2, 3 and 4 m options but states that only the 3 m version is stocked. Ask for availability and delivery time for the selected length rather than assuming every option is in stock.

What should I consider during installation?

Follow the instructions for the supplied version, avoid locations affected by unrelated hot or cold sources, and protect the capillary from flattening or damage. The CTE-2003 reference instructions warn that capillary damage can alter the switching behaviour. Isolate power before electrical work and verify the contact arrangement.

Request a quotation

Email info@heatcoolsmart.com with your application, capillary length, required setpoint, circuit voltage, load type and quantity. Confirm current availability, minimum order quantity and delivery time with the quotation.

For continuous temperature measurement, see the STE-100 duct / immersion temperature sensor and transmitter.

Request Free Quote

Other Products You May Like

QUALITY · RELIABILITY · INNOVATION
Get In Touch With Us
Follow Us
Top