EAS Series electric damper actuators for HVAC, with 6–24 N·m torque options, 24 V AC/DC supply and on/off, 3-point or modulating control versions. Compare the six catalogue models below, then select the control type, feedback requirements and auxiliary-switch configuration for the damper and controller.
| Model | Rated torque |
|---|---|
| EAS-06 | 6 N·m |
| EAS-08 | 8 N·m |
| EAS-10 | 10 N·m |
| EAS-16 | 16 N·m |
| EAS-20 | 20 N·m |
| EAS-24 | 24 N·m |
Choose torque from the damper manufacturer’s requirement and the actual installation. Damper area alone does not establish required torque. The gallery shows two catalogue housing appearances; confirm the housing, shaft fit and mounting details of the selected model.
| Parameter | Catalogue specification |
|---|---|
| Power supply | 24 V AC / 24 V DC |
| Control type | On/off or 3-point |
| Auxiliary switches | 2 × SPDT in the listed catalogue configuration |
| Angle of rotation | Maximum 95° |
| Running time | 30–45 s / 95° |
| Ambient temperature | −20 to +50 °C |
| Protection rating | IP54 |
| Manual override | Yes |
Select on/off control when the system requires open/close operation, or 3-point control when the controller provides the corresponding direction commands. Confirm the ordered configuration, connection diagram and auxiliary-switch availability before installation.
| Parameter | Catalogue specification |
|---|---|
| Power supply | 24 V AC / 24 V DC |
| Control signal options | 0–10 V / 2–10 V / 0–20 mA / 4–20 mA |
| Position feedback options | 0–10 V / 2–10 V / 0–20 mA / 4–20 mA |
| Auxiliary switches | 2 × SPDT in the listed catalogue configuration |
| Angle of rotation | Maximum 95° |
| Running time | 30–45 s / 95° |
| Ambient temperature | −20 to +50 °C |
| Protection rating | IP54 |
| Manual override | Yes |
Control input and position feedback are separate selection requirements. Specify the required signal for each and confirm the supported combination in the ordered version. The listed signals should not be assumed to be simultaneously available at all terminals.
EAS electric damper actuators operate air-control dampers in HVAC applications. Choose the torque and control format to suit the damper load and building automation controller. Where position feedback is needed, specify the controller’s feedback input type separately from its control output.
Confirm the mechanical shaft fit, available installation space, required rotation, running time and auxiliary contacts for the exact supplied model. These details should not be inferred from similar appearances or from a different torque series.
Use the damper manufacturer’s required operating torque and the installation conditions. Provide the damper type, shaft details and required torque when requesting a quotation. Do not apply an unsupported damper-area limit to every model.
On/off is used for open/close commands. A 3-point controller provides directional commands for the corresponding actuator configuration. Modulating control uses a specified analogue input to request position. Match the actuator version to the controller’s output.
No. The control signal requests movement or position; position feedback reports position to a compatible input. For the modulating version, specify both required signal types and confirm their configuration.
The catalogue lists 2 × SPDT for both control groups. The reference documentation distinguishes auxiliary-switch variants, so confirm the full ordering designation and fitted switches rather than assuming every possible variant includes them.
The catalogue gives 30–45 s for 95° rotation for the listed control groups. Specify the selected torque and required running time in the order, and confirm the supplied model’s data before commissioning.
The current catalogue lists six models from 6 to 24 N·m. A 32 N·m designation in reference documents is not included in this catalogue range; request separate confirmation if that torque is needed.
Neither spring-return operation nor fire/smoke-damper certification is stated in the catalogue entry. Specify any fail-safe or certified application requirement separately and confirm an appropriate product.
Email info@heatcoolsmart.com with the EAS model or required torque, control type, control signal, feedback signal, auxiliary-switch requirement, shaft details and quantity. Minimum order quantity, capacity and lead time will be confirmed with the quotation.